Integrated Board

X11DPFF-SN

Available Colors : Black

Key Features
  • Compute Intensive Applications
  • Data Center, HPC and Enterprise Applications
  • Hyperscale, Hyperconverged
  • 4U 8 node systems, each node:
  1. Dual Socket P (LGA 3647) support 2nd Gen. Intel® Xeon® Scalable processors (Cascade Lake/Skylake)‡
  2. 12 DIMMs; up to 3TB 3DS ECC DDR4-2933MHz† RDIMM/LRDIMM, Supports Intel® Optane™ DCPMM††
  3. 1 PCI-E 3.0 x16, 1 PCI-E 3.0 x8 (LP),
    1 PCI-E 3.0 x16 (for SIOM )
  4. 2 or 4 Fixed 2.5" SATA3/NVMe drive bays
    M.2 Interface: 2 SATA/PCI-E 3.0 x4, RAID 0 and 1
    M.2 Form Factor: 2260, 2280, 22110
    M.2 Key: M-Key
  5. Dual GbE ports via SIOM Network card,
    1 dedicated IPMI LAN port (front)
  6. 1 VGA, 2 USB 3.0 ports (front)
  7. 8x 8cm 13.5k RPM rear fans per enclosure
  8. 2200W Redundant Power Supplies Titanium Level (96% Efficiency)

Digital Power 80 PLUS

Product SKUs
SYS-F619P2-FT
  • SuperServer F619P2-FT (Black)
 
Motherboard


Super X11DPFF-SN
 
Processor/Cache (per Node)
CPU
  • Dual Socket P (LGA 3647)
  • 2nd Gen. Intel® Xeon® Scalable Processors (Cascade Lake/Skylake),

    Dual UPI up to 10.4GT/s
  • Support CPU TDP 70-165W with IVR
Cores
  • Up to 28 Cores
Note BIOS version 3.0a or above is required to support 2nd Gen. Intel® Xeon® Scalable processors
 
System Memory (per Node)
Memory Capacity
  • 12 DIMM slots
  • Up to 3TB 3DS ECC DDR4-2933MHz RDIMM/LRDIMM
  • Supports Intel® Optane™ DCPMM††
Memory Type
  • 2933/2666/2400/2133MHz ECC DDR4 RDIMM/LRDIMM
Note 2933MHz in two DIMMs per channel can be achieved by using memory purchased from Supermicro

†† Cascade Lake only. Contact your Supermicro sales rep for more info.
 
On-Board Devices
Chipset
  • Intel® C621 chipset
SATA
  • SATA3 (6Gbps); RAID 0, 1, 5, 10
Network Controllers
  • Flexible networking via SIOM
IPMI
  • Support for Intelligent Platform Management Interface v.2.0
  • IPMI 2.0 with virtual media over LAN and KVM-over-LAN support
Graphics
  • ASPEED AST2500 BMC
 
Input / Output (per node)
SATA
  • 14 SATA3 (6Gbps) ports
LAN
  • SIOM flexible Network card
  • 1 RJ45 Dedicated IPMI LAN port (front)
USB
  • 2 USB 3.0 ports (front)
VGA
  • 1 VGA port (front)
 
System BIOS
BIOS Type
  • 128Mb SPI Flash EEPROM with AMI BIOS
 
Management
Software
Power Configurations
  • ACPI Power Management
 
PC Health Monitoring
CPU
  • Monitors for CPU Cores, Chipset Voltages, Memory.
  • 4+1 Phase-switching voltage regulator
FAN
  • Fans with tachometer monitoring
  • Status monitor for speed control
  • Pulse Width Modulated (PWM) fan connectors
Temperature
  • Monitoring for CPU and chassis environment
  • Thermal Control for fan connectors
Chassis
Form Factor
  • 4U Rackmount
Model
  • CSE-F418IF3-R2K20BP
 
Dimensions and Weight
Width
  • 17.63" (448mm)
Height
  • 6.96" (177mm)
Depth
  • 29" (737mm)
Package
  • 28.3" (W) x 15.0" (H) x 42.4" (D)
Weight
  • Net Weight: 150 lbs (68.04 kg)
  • Gross Weight: 200 lbs (90.71 kg)
Available Colors
  • Black
 
Front Panel
Buttons
  • Power On/Off button
  • UID button
LEDs
  • Power status LED
  • Network activity LEDs
  • Information LED (Fan failure, Overheat)
 
Expansion Slots (per node)
PCI-Express
  • 1 PCI-E 3.0 x16 (Low-profile)
  • 1 PCI-E 3.0 x8 (Low-profile)
  • 1 PCI-E 3.0 x16 (SIOM)
 
Drive Bays (per node)
Fixed
  • 2 or 4 Fixed 2.5" SATA3/NVMe drive bays
M.2
  • M.2 Interface: 2 SATA/PCI-E 3.0 x4, RAID 0 & 1
  • M.2 Form Factor: 2260, 2280, 22110
  • M.2 Key: M-Key
 
System Cooling
Fans
  • 8x 8cm 13.5k RPM rear fans per enclosure
 
Power Supply
2200W Redundant Power Supplies with PMBus
Total Output Power and Input
  • 1200W with Input 100-127Vac
  • 1800W with Input 200-220Vac
  • 1980W with Input 220-230Vac
  • 2090W with Input 230-240Vac
  • 2200W with Input 220-240Vac (for UL/cUL use only)
  • 2090W with Input 230-240Vdc (for CCC only)
AC Input Frequency
  • 50-60Hz
Dimension

(W x H x L)
  • 76 x 40 x 336 mm
+12V
  • Max: 100A / Min: 0A (100-127Vac)
  • Max: 150A / Min: 0A (200-220Vac)
  • Max: 165A / Min: 0A (220-230Vac)
  • Max: 174.17A / Min: 0A (230-240Vac)
  • Max: 183.3A / Min: 0A (220-240Vac)
5VSB
  • Max: 1A / Min: 0A
Output Type
  • Backplanes (gold finger)
Certification Titanium Level96%  Titanium Level

  [ Test Report ]
 
Operating Environment
RoHS
  • RoHS Compliant
Environmental Spec.
  • Operating Temperature:

       10°C ~ 35°C (50°F ~ 95°F)
  • Non-operating Temperature:

       -40°C to 60°C (-40°F to 140°F)
  • Operating Relative Humidity:

       8% to 90% (non-condensing)
  • Non-operating Relative Humidity:

       5% to 95% (non-condensing)


Parts List - (Items Included)
 

Part Number

Qty

Description

Motherboard / Chassis MBD-X11DPFF-SN

CSE-F418IF3-R2K20BP
8

1
Super X11DPFF-SN Motherboard

4U Chassis
Backplane BPN-ADP-X11DPFF 8 Power adapter card for X11DPFF,RoHS
Cable 1 CBL-CDAT-0910 8 CBL,SGPIO,2X5F TO 2X5F,P2.54, 14CM, 24AWG,RoHS
Cable 2 CBL-PWCD-0578 4 PWCD,US,IEC60320 C14 TO C13,3FT,14AWG
Cable 3 CBL-PWEX-1020 16 PWEX,2X4F/P4.2 TO 2X4F/P4.2,10.5CM,16AWG,RoHS
Cable 4 CBL-PWEX-1020-11 16 PWEX,2X4F/P4.2 TO 2X4F/P4.2,10.5CM,16AWG,RoHS
Cable 5 CBL-SAST-0757 8 INT MINI SAS HD to SAS 29px2 + 8p 2x4(5,12V) GPU PWR BLK,50cm,22/30AWG,RoHS/REACH
Riser Card RSC-P-6 8 RSC-P-6 (1U LHS TwinPro RSC with 1 PCI-Ex16),RoHS
Riser Card RSC-R1UF-E16R 8 RSC-R1UF-E16R
Heatsink / Retention SNK-P0067PS 8 1U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism
Heatsink / Retention SNK-P0067PSC 8 1U Passive CPU Heat Sink with a 17-mm Wide Side Air Channel for X11 Purley Platform Equipped with a Narrow Retention Mechanism
* Power Supply PWS-2K04A-1R 4 AC-DC 2000W, Titanium Level, Redundancy, 1U, PMBus 1.2, +12V/+5Vsb, 360x76x40mm,HF,RoHS/REACH
* Power Supply PWS-2K20A-1R 4 1U 2200W Redundant, Titanium, 76(W) X 40(H) X 336(L) mm
* Backplane BPN-PDB-X11DPFF 2 Power Middleplane for X11 FIO Fattwin,RoHS
* Rail Set MCP-290-41803-0N 1 Fat twin F418 / F424 Static Rail set support 28-33.5 inch depth rail,RoHS/REACH,PBF
Notes:
  1. Parts with * are inside the chassis
  2. Excessive parts might not be shipped, including but not limited to excessive drive trays, fans, riser brackets, air shrouds, IO shields, cables.....etc.




Optional Parts List
  Part Number Qty Description
Software SFT-OOB-LIC 1 OOB Management Package (per node license)
Software SFT-DCMS-Single 1 DataCenter Management Package (per node license)
Connect 2x 2.5" NVMe Drive CBL-SAST-0950 1/node 2x OcuLink v 1.0 to 2x PCIe SFF-8639 w/ Power, 35/57CM, 32/24/20 AWG
Connect 4x 2.5" NVMe Drives

*Consult with Technical Support
CBL-SAST-0950
MCP-120-00107-0N
2/node
1/node
2x OcuLink v 1.0 to 2x PCIe SFF-8639 w/ Power, 35/57CM, 32/24/20 AWG
Fixed tool-less 2x 2.5" internal HDD bracket (2nd HDD required screws)
Connect 4x 2.5" SATA Drives

Working Conditions:

• CPU Watts: 165W or lower

• Ambient Temp: 30°C or lower
CBL-SAST-0673
MCP-120-00107-0N
1/node
1/node
MINI SAS HD-SAS 29Px4+2x4P x2,INT,47/47/57/57CM,22/30AWG
Fixed tool-less 2x 2.5" internal HDD bracket (2nd HDD required screws)
Connect 2x 2.5" SAS Drives *Any Qualified LSI Card (Please refer to X11DPFF-SN Tested AOC List) 1/node  
Connect 4x 2.5" SAS Drives

Working Conditions:

• CPU Watts: 125W or lower

• Ambient Temp: 25°C or lower
CBL-SAST-0673
MCP-120-00107-0N
Any Qualified LSI Card (Please refer to X11DPFF-SN Tested AOC List)
1/node
1/node
1/node
MINI SAS HD-SAS 29Px4+2x4P x2,INT,47/47/57/57CM,22/30AWG
Fixed tool-less 2x 2.5" internal HDD bracket (2nd HDD required screws)
-
Software SFT-OOB-LIC 1 OOB Management Package (per node license)
Software SFT-DCMS-Single 1 DataCenter Management Package (per node license)
SuperCap Kit BTR-CV3108-TP2 1/node LSI 3108 CacheVault kit for SIOM based TwinPro, RoHS/REACH
Software SFT-OOB-LIC 1 OOB Management Package (per node license)
Software SFT-DCMS-Single 1 DataCenter Management Package (per node license)